2024-01-12 20:17:36 +01:00
|
|
|
-- IndustrialTest
|
|
|
|
-- Copyright (C) 2024 mrkubax10
|
|
|
|
|
|
|
|
-- This program is free software: you can redistribute it and/or modify
|
|
|
|
-- it under the terms of the GNU General Public License as published by
|
|
|
|
-- the Free Software Foundation, either version 3 of the License, or
|
|
|
|
-- (at your option) any later version.
|
|
|
|
|
|
|
|
-- This program is distributed in the hope that it will be useful,
|
|
|
|
-- but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
-- MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
|
|
-- GNU General Public License for more details.
|
|
|
|
|
|
|
|
-- You should have received a copy of the GNU General Public License
|
|
|
|
-- along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
|
|
|
|
local S=minetest.get_translator("industrialtest")
|
|
|
|
local canningMachine={}
|
|
|
|
|
|
|
|
canningMachine.opPower=200
|
|
|
|
canningMachine.canningTime=5
|
|
|
|
|
|
|
|
canningMachine.getFormspec=function(pos)
|
|
|
|
local meta=minetest.get_meta(pos)
|
|
|
|
local powerPercent=meta:get_int("industrialtest.powerAmount")/meta:get_int("industrialtest.powerCapacity")*100
|
|
|
|
local srcPercent=meta:get_float("srcTime")/canningMachine.canningTime*100
|
2024-05-11 11:54:33 +02:00
|
|
|
local formspec={
|
2024-05-10 19:10:16 +02:00
|
|
|
"list[context;src;3.4,1.8;1,1]",
|
2024-05-11 11:54:33 +02:00
|
|
|
industrialtest.internal.getItemSlotBg(3.4,1.8,1,1),
|
2024-01-12 20:17:36 +01:00
|
|
|
(powerPercent>0 and "image[3.4,2.8;1,1;industrialtest_gui_electricity_bg.png^[lowpart:"..powerPercent..":industrialtest_gui_electricity_fg.png]"
|
|
|
|
or "image[3.4,2.8;1,1;industrialtest_gui_electricity_bg.png]"),
|
|
|
|
"list[context;powerStorage;3.4,3.9;1,1]",
|
2024-05-11 11:54:33 +02:00
|
|
|
industrialtest.internal.getItemSlotBg(3.4,3.9,1,1),
|
2024-01-12 20:17:36 +01:00
|
|
|
(srcPercent>0 and "image[4.9,1.8;1,1;gui_furnace_arrow_bg.png^[lowpart:"..srcPercent..":gui_furnace_arrow_fg.png^[transformR270]"
|
|
|
|
or "image[4.9,1.8;1,1;gui_furnace_arrow_bg.png^[transformR270]"),
|
2024-05-10 19:10:16 +02:00
|
|
|
"list[context;dst;6.4,1.8;1,1]",
|
2024-05-11 11:54:33 +02:00
|
|
|
industrialtest.internal.getItemSlotBg(6.4,1.8,1,1),
|
2024-01-12 20:17:36 +01:00
|
|
|
"list[context;leftover;6.4,2.8;1,1]",
|
2024-05-11 11:54:33 +02:00
|
|
|
industrialtest.internal.getItemSlotBg(6.4,2.8,1,1),
|
2024-01-12 20:17:36 +01:00
|
|
|
"list[context;upgrades;9,0.9;1,4]",
|
2024-05-11 11:54:33 +02:00
|
|
|
industrialtest.internal.getItemSlotBg(9,0.9,1,4),
|
2024-05-10 19:10:16 +02:00
|
|
|
"listring[context;src]",
|
2024-05-11 12:53:18 +02:00
|
|
|
"listring[context;dst]"
|
2024-05-11 11:54:33 +02:00
|
|
|
}
|
2024-01-12 20:17:36 +01:00
|
|
|
return table.concat(formspec,"")
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.onConstruct=function(pos,meta,inv)
|
2024-05-10 19:10:16 +02:00
|
|
|
inv:set_size("src",1)
|
|
|
|
inv:set_size("dst",1)
|
2024-01-12 20:17:36 +01:00
|
|
|
inv:set_size("leftover",1)
|
|
|
|
inv:set_size("powerStorage",1)
|
|
|
|
inv:set_size("upgrades",4)
|
|
|
|
meta:set_float("srcTime",0)
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.onTimer=function(pos,elapsed,meta,inv)
|
|
|
|
local shouldRerunTimer=false
|
|
|
|
local shouldUpdateFormspec=false
|
2024-05-10 19:10:16 +02:00
|
|
|
local fuelSlot=inv:get_stack("src",1)
|
|
|
|
local targetSlot=inv:get_stack("dst",1)
|
2024-01-12 20:17:36 +01:00
|
|
|
local leftoverSlot=inv:get_stack("leftover",1)
|
|
|
|
local powerStorageSlot=inv:get_stack("powerStorage",1)
|
|
|
|
local targetMeta=targetSlot:get_meta()
|
|
|
|
|
2024-03-08 08:56:56 +01:00
|
|
|
shouldRerunTimer,shouldUpdateFormspec=industrialtest.internal.chargeFromPowerStorageItem(meta,inv)
|
2024-01-12 20:17:36 +01:00
|
|
|
|
|
|
|
local def=fuelSlot:get_definition()
|
|
|
|
if not fuelSlot:is_empty() and not targetSlot:is_empty() and meta:get_int("industrialtest.powerAmount")>=canningMachine.opPower and (not def._industrialtest_emptyVariant or leftoverSlot:item_fits(ItemStack(def._industrialtest_emptyVariant))) and
|
|
|
|
(not industrialtest.api.itemHasFluidStorage(fuelSlot) or fuelSlot:get_meta():get_int("industrialtest.fluidAmount")>0) and targetMeta:get_int("industrialtest.fluidAmount")<targetMeta:get_int("industrialtest.fluidCapacity") then
|
|
|
|
minetest.swap_node(pos,{
|
|
|
|
name="industrialtest:canning_machine_active",
|
|
|
|
param2=minetest.get_node(pos).param2
|
|
|
|
})
|
|
|
|
minetest.get_node_timer(pos):start(industrialtest.updateDelay)
|
|
|
|
return false,shouldUpdateFormspec
|
|
|
|
end
|
|
|
|
|
|
|
|
return shouldRerunTimer,true
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.allowMetadataInventoryMove=function(pos,fromList,fromIndex,toList,count)
|
2024-05-10 19:10:16 +02:00
|
|
|
if toList=="src" then
|
2024-01-12 20:17:36 +01:00
|
|
|
local inv=minetest.get_meta(pos):get_inventory()
|
|
|
|
local itemstack=inv:get_stack(fromList,fromIndex)
|
|
|
|
local def=itemstack:get_definition()
|
|
|
|
return (def.groups and def.groups._industrialtest_fuel) and count or 0
|
|
|
|
end
|
2024-05-10 19:10:16 +02:00
|
|
|
if toList=="dst" then
|
2024-01-12 20:17:36 +01:00
|
|
|
local inv=minetest.get_meta(pos):get_inventory()
|
|
|
|
local itemstack=inv:get_stack(fromList,fromIndex)
|
|
|
|
local def=itemstack:get_definition()
|
|
|
|
return (def.groups and def.groups._industrialtest_fueled) and count or 0
|
|
|
|
end
|
|
|
|
return count
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.allowMetadataInventoryPut=function(pos,listname,index,stack)
|
2024-05-10 19:10:16 +02:00
|
|
|
if listname=="src" then
|
2024-01-12 20:17:36 +01:00
|
|
|
local def=stack:get_definition()
|
|
|
|
return (def.groups and def.groups._industrialtest_fuel) and stack:get_count() or 0
|
|
|
|
end
|
2024-05-10 19:10:16 +02:00
|
|
|
if listname=="dst" then
|
2024-01-12 20:17:36 +01:00
|
|
|
local def=stack:get_definition()
|
|
|
|
return (def.groups and def.groups._industrialtest_fueled) and stack:get_count() or 0
|
|
|
|
end
|
|
|
|
return stack:get_count()
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.allowMetadataInventoryTake=function(pos,listname,index,stack)
|
|
|
|
local meta=minetest.get_meta(pos)
|
|
|
|
local inv=meta:get_inventory()
|
2024-05-10 19:10:16 +02:00
|
|
|
local fuelSlot=inv:get_stack("src",1)
|
|
|
|
local targetSlot=inv:get_stack("dst",1)
|
|
|
|
if ((listname=="src" and stack:get_count()==fuelSlot:get_count()) or (listname=="dst" and stack:get_count()==targetSlot:get_count())) and meta:get_float("srcTime")>0 then
|
2024-01-12 20:17:36 +01:00
|
|
|
meta:set_float("srcTime",0)
|
|
|
|
minetest.get_node_timer(pos):start(industrialtest.updateDelay)
|
|
|
|
end
|
|
|
|
return stack:get_count()
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.onMetadataInventoryPut=function(pos)
|
|
|
|
minetest.get_node_timer(pos):start(industrialtest.updateDelay)
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.onMetadataInventoryMove=function(pos,fromList,fromIndex,toList,toIndex,count)
|
|
|
|
local meta=minetest.get_meta(pos)
|
|
|
|
local inv=meta:get_inventory()
|
2024-05-10 19:10:16 +02:00
|
|
|
local fuelSlot=inv:get_stack("src",1)
|
|
|
|
local targetSlot=inv:get_stack("dst",1)
|
|
|
|
if ((fromList=="src" and count==fuelSlot:get_count()) or (fromList=="dst" and count==targetSlot:get_count())) and meta:get_float("srcTime")>0 then
|
2024-01-12 20:17:36 +01:00
|
|
|
meta:set_float("srcTime",0)
|
|
|
|
meta:set_string("formspec",canningMachine.getFormspec(pos))
|
|
|
|
end
|
|
|
|
end
|
|
|
|
|
|
|
|
canningMachine.activeOnTimer=function(pos,elapsed,meta,inv)
|
|
|
|
local shouldUpdateFormspec=false
|
2024-05-10 19:10:16 +02:00
|
|
|
local fuelSlot=inv:get_stack("src",1)
|
|
|
|
local targetSlot=inv:get_stack("dst",1)
|
2024-01-12 20:17:36 +01:00
|
|
|
local powerStorageSlot=inv:get_stack("powerStorage",1)
|
|
|
|
|
2024-03-08 08:56:56 +01:00
|
|
|
shouldRerunTimer,shouldUpdateFormspec=industrialtest.internal.chargeFromPowerStorageItem(meta,inv)
|
2024-01-12 20:17:36 +01:00
|
|
|
|
|
|
|
if fuelSlot:is_empty() or targetSlot:is_empty() or meta:get_int("industrialtest.powerAmount")<canningMachine.opPower then
|
|
|
|
if meta:get_int("industrialtest.powerAmount")>=canningMachine.opPower then
|
|
|
|
meta:set_float("srcTime",0)
|
|
|
|
end
|
|
|
|
minetest.swap_node(pos,{
|
|
|
|
name="industrialtest:canning_machine",
|
|
|
|
param2=minetest.get_node(pos).param2
|
|
|
|
})
|
|
|
|
minetest.get_node_timer(pos):start(industrialtest.updateDelay)
|
|
|
|
return false,true
|
|
|
|
end
|
|
|
|
|
|
|
|
local fuelMeta=fuelSlot:get_meta()
|
|
|
|
local targetMeta=targetSlot:get_meta()
|
|
|
|
if (industrialtest.api.itemHasFluidStorage(fuelSlot) and fuelMeta:get_int("industrialtest.fluidAmount")==0) or targetMeta:get_int("industrialtest.fluidAmount")==targetMeta:get_int("industrialtest.fluidCapacity") then
|
|
|
|
meta:set_float("srcTime",0)
|
|
|
|
minetest.swap_node(pos,{
|
|
|
|
name="industrialtest:canning_machine",
|
|
|
|
param2=minetest.get_node(pos).param2
|
|
|
|
})
|
|
|
|
minetest.get_node_timer(pos):start(industrialtest.updateDelay)
|
|
|
|
return false,true
|
|
|
|
end
|
|
|
|
|
|
|
|
local srcTime=meta:get_float("srcTime")
|
|
|
|
srcTime=srcTime+elapsed*industrialtest.api.getMachineSpeed(meta)
|
|
|
|
if srcTime>=canningMachine.canningTime then
|
|
|
|
if industrialtest.api.itemHasFluidStorage(fuelSlot) then
|
|
|
|
industrialtest.api.transferFluidToItem(fuelSlot,targetSlot,fuelMeta:get_int("industrialtest.fluidAmount"))
|
2024-05-10 19:10:16 +02:00
|
|
|
inv:set_stack("src",1,fuelSlot)
|
|
|
|
inv:set_stack("dst",1,targetSlot)
|
2024-01-12 20:17:36 +01:00
|
|
|
else
|
|
|
|
local def=fuelSlot:get_definition()
|
|
|
|
local leftoverSlot=inv:get_stack("leftover",1)
|
|
|
|
if targetMeta:get_int("industrialtest.fluidCapacity")-targetMeta:get_int("industrialtest.fluidAmount")<def._industrialtest_fuelAmount or (def._industrialtest_emptyVariant and not leftoverSlot:item_fits(ItemStack(def._industrialtest_emptyVariant))) then
|
|
|
|
minetest.swap_node(pos,{
|
|
|
|
name="industrialtest:canning_machine",
|
|
|
|
param2=minetest.get_node(pos).param2
|
|
|
|
})
|
|
|
|
minetest.get_node_timer(pos):start(industrialtest.updateDelay)
|
|
|
|
return false,shouldUpdateFormspec
|
|
|
|
end
|
|
|
|
industrialtest.api.addFluidToItem(targetSlot,def._industrialtest_fuelAmount)
|
2024-05-10 19:10:16 +02:00
|
|
|
inv:set_stack("dst",1,targetSlot)
|
2024-01-12 20:17:36 +01:00
|
|
|
fuelSlot:take_item(1)
|
2024-05-10 19:10:16 +02:00
|
|
|
inv:set_stack("src",1,fuelSlot)
|
2024-01-12 20:17:36 +01:00
|
|
|
leftoverSlot:add_item(ItemStack(def._industrialtest_emptyVariant))
|
|
|
|
inv:set_stack("leftover",1,leftoverSlot)
|
|
|
|
end
|
|
|
|
meta:set_float("srcTime",0)
|
|
|
|
else
|
|
|
|
meta:set_float("srcTime",srcTime)
|
|
|
|
end
|
|
|
|
industrialtest.api.addPower(meta,-canningMachine.opPower)
|
|
|
|
|
|
|
|
return true,true
|
|
|
|
end
|
|
|
|
|
|
|
|
industrialtest.internal.registerMachine({
|
|
|
|
name="canning_machine",
|
|
|
|
displayName=S("Canning Machine"),
|
|
|
|
capacity=industrialtest.api.lvPowerFlow*2,
|
|
|
|
getFormspec=canningMachine.getFormspec,
|
|
|
|
flow=industrialtest.api.lvPowerFlow,
|
|
|
|
ioConfig="iiiiii",
|
|
|
|
requiresWrench=true,
|
|
|
|
registerActiveVariant=true,
|
|
|
|
sounds="metal",
|
|
|
|
powerSlots={"powerStorage"},
|
2024-05-10 19:10:16 +02:00
|
|
|
storageSlots={"src","dst","powerStorage","upgrades"},
|
2024-01-12 20:17:36 +01:00
|
|
|
groups={
|
|
|
|
_industrialtest_hasPowerInput=1
|
|
|
|
},
|
|
|
|
customKeys={
|
|
|
|
tiles={
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png^industrialtest_canning_machine_front.png"
|
|
|
|
},
|
|
|
|
paramtype2="facedir",
|
|
|
|
legacy_facedir_simple=true
|
|
|
|
},
|
|
|
|
activeCustomKeys={
|
|
|
|
tiles={
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png",
|
|
|
|
"industrialtest_machine_block.png^industrialtest_canning_machine_front_active.png"
|
|
|
|
}
|
|
|
|
},
|
|
|
|
onConstruct=canningMachine.onConstruct,
|
|
|
|
onTimer=canningMachine.onTimer,
|
|
|
|
allowMetadataInventoryMove=canningMachine.allowMetadataInventoryMove,
|
|
|
|
allowMetadataInventoryPut=canningMachine.allowMetadataInventoryPut,
|
|
|
|
allowMetadataInventoryTake=canningMachine.allowMetadataInventoryTake,
|
|
|
|
onMetadataInventoryPut=canningMachine.onMetadataInventoryPut,
|
|
|
|
onMetadataInventoryMove=canningMachine.onMetadataInventoryMove,
|
|
|
|
activeOnTimer=canningMachine.activeOnTimer
|
|
|
|
})
|
|
|
|
minetest.register_craft({
|
|
|
|
type="shaped",
|
|
|
|
output="industrialtest:canning_machine",
|
|
|
|
recipe={
|
|
|
|
{industrialtest.elementKeys.tinIngot,"industrialtest:electronic_circuit",industrialtest.elementKeys.tinIngot},
|
|
|
|
{industrialtest.elementKeys.tinIngot,"industrialtest:machine_block",industrialtest.elementKeys.tinIngot},
|
|
|
|
{industrialtest.elementKeys.tinIngot,industrialtest.elementKeys.tinIngot,industrialtest.elementKeys.tinIngot}
|
|
|
|
}
|
|
|
|
})
|